TRAKLOC STUDS (TLF)
NON-Composite Maximum Allowable Wall Heights

Values below are listed in the ICC ESR-1464 report.

Click the below Member to view individual Tech Datasheet / Submittal

Member Spacing
(in)
on center
5 PSF
L/120 L/240 L/360

250TLF125-18

2-1/2" 25ga
 

12" 13'-0" 11'-1" 9'-8"
16" 11'-3" 10'-1" 8'-9"

24"

8'-10” 8'-10" 7'-8"

250TLF125-30

2-1/2" 20ga (DW)

12" 16'-5" 13'-0" 11'-5"
16" 14'-11" 11'-10" 10'-4"
24" 12'-7" 10'-4" 9'-0"

250TLF125-33

2-1/2" 20ga

12" 17'-0" 13'-6" 11'-9"
16" 15'-5" 12'-3" 10'-8"
24" 13'-6" 10'-8" 9'-4"
 

362TLF125-18

3-5/8" 25ga

12" 15'-10" 14'-9" 12'-11"
16" 13'-6" 13'-5" 11'-9"
24" 9'-0" 9'-0" 9'-0"

362TLF125-30

3-5/8" 20ga (DW)

12" 21'-11" 17'-5" 15'-2"
16" 19'-1" 15'-10" 13'-9"
24" 15'-7" 13'-9" 12'-1"

362TLF125-33

3-5/8" 20ga

12" 22'-8" 18'-0" 15'-8"
16" 20'-7" 16'-4" 14'-3"
24" 17'-8" 14'-3" 12'-5"
 

400TLF125-18

4" 25ga

12" 16'-6" 14'-8" 12'-10"
16" 14'-4" 13'-4" 11'-7"
24" 11'-8" 11'-7" 10'-2"

400TLF125-30

4" 20ga (DW)

12" 22-8" 18'-0" 15'-9"
16" 20'-4" 16'-4" 14'-3"
24" 16'-7" 14'-3" 12'-6"

400TLF125-33

4" 20ga

12" 23'-7" 18'-9" 16'-4"
16" 21'-5" 17'-0" 14'-10"
24" 17'-9" 14'-10" 13'-0"
 

600TLF125-30

6" 20ga (DW)

12" 30'-11" 25'-8" 22'-5"
16" 26'-9" 23'-4" 20'-5"
24" 21'-10" 20'-5" 17'-10"

600TLF125-33

6" 20ga

12" 33'-3" 26'-8" 23'-3"
16" 28'-10" 24'-3" 21'-2"
24" 23'-6" 21'-2" 18'-6"
Table notes:
  • TRAKLOC® products section properties and non-composite limiting wall heights were determined in accordance with AISI S100-07 with S2-10 - North American Specification for the Design of Cold-Formed Steel Members, 2007 edition with S2-10.
  • 7.5 PSF and 10 PSF tables abailable in product submittals or in the Limiting Heights page from the TRAKLOC catalog.
  • 6" 18 mil available upon request

 

  • Contact ClarkDietrich Technical Services at 888-437-3244 for any questions about ClarkDietrich's TRAKLOC Limiting Heights.